18 research outputs found

    小脳への経頭蓋直流電流刺激が立位姿勢制御に与える影響

    Get PDF
    Frontiers in Human Neuroscience. 2016, 10, Article325博士(保健学)新潟医療福祉大

    Probing dynamics of carbon dioxide in a metal-organic framework under high pressure by high-resolution solid-state NMR

    Get PDF
    The application of high-resolution NMR analysis for CO2 adsorbed in an MOF under high pressure is reported for the first time. The results showed that CO2 adsorbed in MOF-74 had a unusual slow mobility (τ ~ 10-8 s). CO2–CO2 interactions suppressed the mobility of CO2 under high pressure, which, in turn, would have contributed to the stability of CO2 at adsorption sites

    Repetitive Passive Finger Movement Modulates Primary Somatosensory Cortex Excitability

    Get PDF
    Somatosensory inputs induced by repetitive passive movement (RPM) modulate primary motor cortex (M1) excitability; however, it is unclear whether RPM affects primary somatosensory cortex (S1) excitability. In this study, we investigated whether RPM affects somatosensory evoked potentials (SEPs) and resting state brain oscillation, including alpha and beta bands, depend on RPM frequency. Nineteen healthy subjects participated in this study, and SEPs elicited by peripheral nerve electrical stimulation were recorded from the C3’ area in order to assess S1 excitability (Exp. 1: n = 15). We focused on prominent SEP components such as N20, P25 and P45-reflecting S1 activities. In addition, resting electroencephalograms (EEGs) were recorded from C3’ area to assess the internal state of the brain network at rest (Exp. 2: n = 15). Passive abduction/adduction of the right index finger was applied for 10 min at frequencies of 0.5, 1.0, 3.0, and 5.0 Hz in Exp. 1, and 1.0, 3.0, and 5.0 Hz in Exp. 2. No changes in N20 or P25 components were observed following RPM. The 3.0 Hz-RPM decreased the P45 component for 20 min (p < 0.05), but otherwise did not affect the P45 component. There was no difference in the alpha and beta bands before and after any RPM; however, a negative correlation was observed between the rate of change of beta power and P45 component at 3.0 Hz-RPM. Our findings indicated that the P45 component changes depending on the RPM frequency, suggesting that somatosensory inputs induced by RPM influences S1 excitability. Additionally, beta power enhancement appears to contribute to the P45 component depression in 3.0 Hz-RPM

    Repetitive Passive Movement Modulates Corticospinal Excitability: Effect of Movement and Rest Cycles and Subject Attention

    Get PDF
    Repetitive passive movement (PM) affects corticospinal excitability; however, it is unknown whether a duty cycle which repeats movement and rest, or subjects’ conscious attention to movements, affects corticospinal excitability. We aimed to clarify the effect of the presence or absence of a duty cycle and subjects’ attention on corticospinal excitability. Three experiments were conducted. In Experiment 1, PM of the right index finger was performed for 10 min. Three conditions were used: (1) continuous PM (cPM) at a rate of 40°/s; (2) intermittent PM (iPM) with a duty cycle at 40°/s; and (3) iPM at 100°/s. In conditions 1 and 3, motor evoked potential (MEP) amplitude was significantly reduced. In Experiment 2, PM was performed for 30 min: condition 1 comprised cPM at a rate of 40°/s and Condition 2 comprised iPM at 40°/s. MEP amplitude significantly decreased in both conditions. In Experiment 3, PM was performed for 10 min: condition 1 comprised paying attention to the moving finger during iPM and Condition 2 was similar to Condition 1 but while counting images on a monitor without looking at the movement finger, and Condition 3 comprised counting images on a monitor without performing PM. MEP amplitude significantly increased only under Condition 1. Thus, afferent input from movements above a certain threshold may affect corticospinal excitability reduction. Furthermore, corticospinal excitability increases when paying attention to passive finger movement

    Nondestructive high-resolution solid-state NMR of rotating thin films at the magic-angle.

    Get PDF
    We present a new approach to nondestructive magic-angle spinning (MAS) nuclear magnetic resonance (NMR) for thin films. In this scheme, the sample put on the top of a rotor is spun using the conventional MAS system, and the NMR signals are detected with an additional coil. Stable spinning of disk-shaped samples with diameters of 7mm and 12mm at 14.2 and 7kHz are feasible. We present (7)Li MAS NMR experiments of a thin-film sample of LiCoO(2) with a thickness of 200nm. Taking advantage of the nondestructive feature of the experiment, we also demonstrate ex situ experiments, by tracing conformation change upon annealing for various durations. This approach opens the door for in situ MAS NMR of thin-film devices as well

    Influence of Transcranial Direct Current Stimulation to the Cerebellum on Standing Posture Control

    No full text
    Damage to the vestibular cerebellum results in dysfunctional standing posture control. Patients with cerebellum dysfunction have a larger sway in the center of gravity while standing compared with healthy subjects. Transcranial direct current stimulation (tDCS) is a noninvasive technique for selectively exciting or inhibiting specific neural structures with potential applications in functional assessment and treatment of neural disorders. However, the specific stimulation parameters for influencing postural control have not been assessed. In this study, we investigated the influence of tDCS when applied over the cerebellum on standing posture control. Sixteen healthy subjects received tDCS (20 min, 2 mA) over the scalp 2 cm below the inion. In experiment 1, all 16 subjects received tDCS under three stimulus conditions, Sham, Cathodal, and Anodal, in a random order with the second electrode placed on the forehead. In experiment 2, five subjects received cathodal stimulation only with the second electrode placed over the right buccinator muscle. Center of gravity sway was measured twice for 60 s before and after tDCS in a standing posture with eyes open and legs closed, and average total locus length, locus length per second, rectangular area, and enveloped area were calculated. In experiment 1, total locus length and locus length per second decreased significantly after cathodal stimulation but not after anodal or sham stimulation, while no tDCS condition influenced rectangular or enveloped areas. In experiment 2, cathodal tDCS again significantly reduced total locus length and locus length per second but not rectangular and enveloped areas. The effects of tDCS on postural control are polarity-dependent, likely reflecting the selective excitation or inhibition of cerebellar Purkinje cells. Cathodal tDCS to the cerebellum of healthy subjects can alter body sway (velocity)

    Transcranial Alternating Current Stimulation With Gamma Oscillations Over the Primary Motor Cortex and Cerebellar Hemisphere Improved Visuomotor Performance

    No full text
    Transcranial alternating current stimulation (tACS) can be used to modulate oscillatory brain activity. In this study, we investigated whether tACS applied over the primary motor cortex (M1) and cerebellar cortex region improved motor performance. We applied tACS (1.0 mA) to 20 healthy adults while they performed an isometric force task with some visuomotor control using their right index finger. Gamma (70 Hz) oscillations in the Experiment 1 or beta (20 Hz) oscillations in the Experiment 2 were applied for 30 s over the left M1, right cerebellar hemisphere or both regions (“M1-Cerebellum”), and errors performing the task were compared. Beta-oscillation tACS did not affect motor performance. With the gamma-oscillation tACS, a negative correlation was found between the difference of error in the M1-Cerebellum condition and the number of errors in the sham condition (P = 0.005, Pearson’s r = −0.597), indicating that motor performance improved with M1-Cerebellum tACS for subjects with low motor performance in the sham condition. Those who performed poorly in the sham condition made significantly fewer errors with M1-Cerebellum tACS (P = 0.004). Thus, for subjects with poorer motor performance, tACS with gamma oscillations applied over the M1 and contralateral cerebellar hemisphere improved their performance

    Effect of noisy galvanic vestibular stimulation in community-dwelling elderly people: a randomised controlled trial

    No full text
    Abstract Background Balance disorders are a risk factor for falls in the elderly. Although noisy galvanic vestibular stimulation (nGVS) has been reported to improve balance in young people, randomised control trials targeting community-dwelling elderly people have not been conducted to date. We aimed to assess the influence of nGVS on COP sway in the open-eye standing posture among community-dwelling elderly people in a randomised controlled trial. Methods A randomised controlled trial of 32 community-dwelling elderly people randomly assigned to control (sham stimulation) and an nGVS groups. All participants underwent centre of pressure (COP) sway measurements while standing with open eyes at baseline and during stimulation. The control group underwent sham stimulation and the nGVS group underwent noise stimulation (0.4 mA; 0.1–640 Hz). Results In the nGVS group, sway path length, mediolateral mean velocity and anteroposterior mean velocity decreased during stimulation compared with baseline (P < 0.01). The effect of nGVS was large in participants with a high COP sway path length at baseline, but there was no significant difference in COP sway in the control group. Conclusions We conclude that nGVS decreases the COP sway path length and mean velocity of community-dwelling elderly people when standing with open eyes. This suggests that nGVS could be effective for treating balance dysfunction in the elderly

    Effects of Passive Finger Movement on Cortical Excitability

    No full text
    This study examined the effects of joint angle and passive movement direction on corticospinal excitability. The subjects were 14 healthy adults from whom consent could be obtained. We performed two experiments. In Experiment 1, we measured motor evoked potential (MEP) amplitude, F-wave and M-wave at 0° and 20° adduction during adduction or abduction movement, in the range of movement from 10° abduction to 30° adduction. In Experiment 2, MEPs were measured at static 0° and 20° adduction during passive adduction from 10° adduction to 30° adduction and static 20° adduction. MEP, F-waves and M-waves were recorded from the right first dorsal interosseous (FDI) muscle. Experiment 1 revealed significantly increased MEP amplitude at 0° during passive adduction compared to static 0° (p &lt; 0.01). No other significant differences in MEP, M-wave and F-wave parameters were observed. In Experiment 2, MEP amplitude was significantly higher at 20° adduction during passive adduction compared with static 0° (p &lt; 0.01). Based on these findings, it appears that fluctuations in MEP amplitude values during passive movement are not influenced by joint angle, but rather it is possible that it is due to intracortical afferent facilitation (AF) dependent on afferent input due to the start of movement and interstimulus interval (ISI) of transcranial magnetic stimulation (TMS)
    corecore